Schedule 40 vs Schedule 80 Steel Pipe: How to Choose the Right Wall Thickness
Explore galvanized steel pipe sizes, OD, wall thickness, and schedule 40 charts. Learn how to measure galvanized pipe size and astm a53 specifications.
Luyuan Steel Technical Team | Published September 2026
A “2 inch” galvanized pipe has an actual outside diameter of 60.3 mm, not 2 inches (50.8 mm) — NPS and DN are naming conventions, not measurements. This guide gives the real OD and wall thickness for the sizes ordered most often, plus where SHS/RHS square tube uses a completely different sizing system.

Abmessungen verzinkter Stahlrohre: NPS, DN und Wandstärken
Nominal Pipe Size (NPS, used in North America and much of Asia’s English-language documentation) and Diamètre Nominal (DN, the metric equivalent used across Europe and in most mill certificates) both describe a size class, not a physical measurement. NPS 2 and DN50 refer to the same pipe. Neither number matches the pipe’s actual outside diameter once you check a schedule table — NPS 2 has an actual OD of 60.3 mm, and that OD stays fixed across every wall thickness in that size class. A Schedule 40 NPS 2 pipe and a Schedule 80 NPS 2 pipe share the same 60.3 mm outside diameter; only the wall thickness, and therefore the inside diameter, changes. This is the detail that causes the most fitting and threading errors on a jobsite: assuming “2 inch pipe” is one fixed product instead of a size family with several wall options inside it.
The table below covers the sizes buyers search for most, cross-referencing NPS, DN, actual outside diameter, and wall thickness at the two most commonly specified schedules.
| NPS | DN | OD (mm) | OD (in) | Sch 40 Wall (mm) | Wanddicke Sch 80 (mm) |
| 1/2″ | DN15 | 21.3 | 0.840 | 2.77 | 3.73 |
| 3/4″ | DN20 | 26.7 | 1.050 | 2.87 | 3.91 |
| 1″ | DN25 | 33.4 | 1.315 | 3.38 | 4.55 |
| 1-1/4″ | DN32 | 42.2 | 1.660 | 3.56 | 4.85 |
| 1-1/2″ | DN40 | 48.3 | 1.900 | 3.68 | 5.08 |
| 2″ | DN50 | 60.3 | 2.375 | 3.91 | 5.54 |
| 2-1/2″ | DN65 | 73.0 | 2.875 | 5.16 | 7.01 |
| 3″ | DN80 | 88.9 | 3.500 | 5.49 | 7.62 |
| 4″ | DN100 | 114.3 | 4.500 | 6.02 | 8.56 |
These dimensions follow the schedule conventions set out under ASTM pipe specifications such as ASTM A53, which governs black and hot-dip galvanized welded and seamless steel pipe. They hold regardless of which mill supplies the pipe — the OD-to-schedule relationship is a standard, not a proprietary spec.
Schedule number describes wall thickness relative to pressure rating, not overall size. A 3″ Schedule 40 pipe and a 3″ Schedule 80 pipe both measure 88.9 mm OD — the Schedule 80 version simply has a thicker wall (7.62 mm versus 5.49 mm) and a correspondingly smaller bore. This matters for two practical reasons. First, threaded fittings are cut to match the OD, so Schedule 40 and Schedule 80 pipe in the same NPS thread onto the same fittings. Second, flow capacity drops as schedule increases, since the thicker wall eats into the usable bore — a detail worth checking before defaulting to Schedule 80 “for strength” on a run where flow rate actually matters more than pressure rating.

Abmessungen verzinkter Stahlrohre: NPS, DN und Wandstärken
“Galvanized steel pipe” bezeichnet ein Beschichtungsverfahren und kein einzelnes, fest definiertes Produkt; auch ergeben sich die Einzelheiten der Beschichtung nicht automatisch aus der NPS-/DN-Größenangabe. Feuerverzinkte Rohre (nach der Fertigung in geschmolzenes Zink getaucht, wobei für gefertigte Stahlbauteile üblicherweise auf ASTM A123 oder auf die Beschichtungsbestimmungen in ASTM A53 verwiesen wird) und kontinuierlich verzinkte oder aus vorverzinktem Band geformte Rohre sind nicht dasselbe Produkt und weisen weder dasselbe Zinkauflagegewicht noch dieselbe Korrosionsbeständigkeit auf. In Luyuans derzeit veröffentlichten Rohrangeboten ist für die einzelnen Rohrprodukte keine bestimmte Zinkbeschichtungsklasse angegeben. Diese sollte bereits bei der Angebotsanfrage direkt anhand Ihrer Projektspezifikation bestätigt und nicht allein aus dem Wort “verzinkt” abgeleitet werden. Wenn Ihre Spezifikation ein bestimmtes Beschichtungsgewicht oder eine bestimmte Verzinkungsnorm vorschreibt, führen Sie diese Anforderung schriftlich in der Angebotsanfrage auf und nicht nur im Produktnamen.
Square Hollow Section (SHS) and Rectangular Hollow Section (RHS) pipe are sized by cross-section dimension in millimeters — for example 50×50 mm or 100×50 mm — with a separate wall thickness callout, not by NPS or DN. Luyuan’s SHS/RHS line is produced in Q235 and Q355 grades, using the ERW (electric resistance welding) process, in standard 6 m and 12 m lengths. If a project genuinely calls for square or rectangular tube rather than round pipe, size it by section dimension and wall thickness directly — NPS/DN conversion tables don’t apply to this product family, and requesting an “NPS equivalent” for SHS/RHS will produce a mismatched quote.
For round pipe sized under the NPS/DN system covered above, Luyuan’s catalog centers on two product lines. Geschweißtes Rohr is produced in Q235B and Q355B grades using ERW or EFW (electric fusion welding) processes, in a standard 6 m length. Seamless Pipe is available under ASTM A106, ASTM A53, or API 5L material options, with outside diameters from 10 mm to 700 mm and lengths from 6 to 12 meters, or cut to custom length. Both processes are compatible with the OD/wall relationships in the master table above; which one fits a given project depends more on pressure rating and joint integrity requirements than on size alone — seamless pipe is generally specified where a continuous, weld-seam-free wall is required for higher-pressure service.

Abmessungen verzinkter Stahlrohre: NPS, DN und Wandstärken
Luyuan’s published reference price for galvanized steel Rohre runs approximately USD 608–623 per metric ton. This range is indicative, not a fixed quote — final pricing depends on grade, wall schedule, coating specification, length, and order volume, plus Incoterms and destination. Where a specific coating class or a less common size falls outside this published range, treat it as price on request rather than assuming the published band applies uniformly across every schedule and coating combination.
Der häufigste Fehler besteht darin, nur nach NPS zu bestellen und davon auszugehen, dass die Rohrwanddickenklasse damit impliziert sei. Wenn ein Lieferant Schedule 40 anbietet, obwohl in der Spezifikation Schedule 80 vorgeschrieben ist, liefert er ein Rohr mit dem richtigen Außendurchmesser, aber der falschen Wanddicke. Dies fällt oft erst auf, wenn das Rohr eine Druckprüfung nicht besteht. Der zweithäufigste Fehler besteht darin, DN und NPS als direkt austauschbar zu betrachten, ohne zu prüfen, ob beide Parteien dieselbe Rohrwanddickentabelle verwenden. DN50 und NPS 2 bezeichnen dasselbe Rohr; gibt ein Käufer gegenüber einem Lieferanten, der mit zollbasierten Unterlagen arbeitet, jedoch “DN50” an, kann es zu einem falschen Außendurchmesser kommen, wenn die Umrechnung nicht schriftlich bestätigt wird. Der dritte Fehler besteht darin, “verzinkt” ohne Angabe einer Beschichtungsnorm anzufordern. Dadurch richten sich Auflagegewicht und Verfahren nach dem Standard des Werks und nicht nach den tatsächlichen Korrosionsschutzanforderungen des Projekts.
A: No. NPS 2 has an actual outside diameter of 60.3 mm (2.375 in) — the “2 inch” label is a size class name, not a physical measurement.
A: They’re the same size classification system expressed in two units — NPS in inches (common in North America and English-language specs), DN in millimeters (common in European and international documentation). NPS 2 equals DN50.
A: Neither — both share the same OD within a given NPS/DN size. Schedule 80 has a thicker wall and smaller inside diameter than Schedule 40 at the same nominal size.
A: NPS 1 / DN25 has an actual outside diameter of 33.4 mm, with a Schedule 40 wall thickness of 3.38 mm.
A: No. SHS/RHS square and rectangular tube is sized by cross-section dimension in millimeters (e.g., 50×50 mm) plus wall thickness, not by NPS or DN — the two systems aren’t interchangeable.
A: This depends on your project spec; hot-dip galvanizing is commonly referenced against ASTM A123. Confirm the specific coating weight and standard with your supplier in writing, since it’s not always implied by the word “galvanized” alone.
A: Both. Seamless pipe is available under ASTM A106, ASTM A53, or API 5L with OD 10–700 mm; welded pipe is available in Q235B/Q355B grades via ERW or EFW in standard 6 m lengths.
A: Luyuan’s reference range is approximately USD 608–623 per metric ton, varying with grade, schedule, coating, and volume — confirm current pricing and coating specification at RFQ stage.
A: An English Mill Test Certificate at minimum, plus third-party inspection (SGS, BV, Intertek, or buyer-appointed) on request before shipment.
Explore galvanized steel pipe sizes, OD, wall thickness, and schedule 40 charts. Learn how to measure galvanized pipe size and astm a53 specifications.
Compare plain round bar and deformed bar in this steel reinforcement guide. Learn which type of steel bar and rebar is best for your construction project.
Wir antworten Ihnen innerhalb von 24 Stunden. In dringenden Fällen fügen Sie bitte WhatsApp/WeChat hinzu: +86 15066120072. Oder rufen Sie direkt unter +86 15066120072 an.
*Wir respektieren Ihre Vertraulichkeit und alle Informationen werden geschützt.
Wir verwenden Ihre Informationen ausschließlich, um auf Ihre Anfrage zu antworten, und senden Ihnen niemals unaufgeforderte E-Mails oder Werbenachrichten.